Add a small periodic disturbance to an active oscillator’s supply and two narrow lines may appear on either side of the carrier. Their offset matches the supply disturbance frequency. This ties a component at that frequency to the output. For design or purchasing, the next question is whether amplitude, edge timing or both are affected. An ordinary spectrum shows line power without the phase of the sidebands relative to the carrier. Amplitude modulation and small-signal phase modulation can both produce symmetric sidebands. Calculating time jitter from that plot alone may count AM as jitter.
Equal sideband power can represent different effects
Picture an arrow rotating at a constant rate. Its length represents sine-wave amplitude and its direction represents phase. Periodic changes in length move the envelope, while periodic advances and delays in angle perturb carrier phase. If both changes have the same frequency, their sidebands land at the same offsets. Even if an AM signal and a PM signal produce sidebands of equal height, their in-phase and quadrature components can differ. Rohde & Schwarz notes in its description of the spectrum analysis method that conventional spectral analysis cannot distinguish AM noise from phase noise. Suitable IQ data can help. IQ measurement resolves the signal into two components relative to a reference. Demodulation then separates radial changes from angular changes.
In a supply immunity test, observe injected voltage and output together. Filtering between the injection point and the oscillator can change the ripple. Use an appropriate probe near the supply pin rather than taking the generator display as the pin voltage. Keep the mean and excursions within specified operating limits and connect the recommended output load. Save a baseline with no injection, then try several small amplitudes at the same frequency. If the lines track the injected signal, decide whether separate AM and PM measurements are needed. Lines present before injection warrant checking the supply, reference and other periodic sources.
What can sideband height alone tell you?
Worked example with assumed values. A 10 MHz sine oscillator has one discrete line on each side, both 40 dB below the carrier. Each sideband-to-carrier amplitude ratio is 0.01. For sinusoidal AM alone at low modulation depth, each sideband amplitude is about half the modulation index times the carrier amplitude. The result is about 2% amplitude modulation. For small-angle PM alone, each amplitude ratio is about half the peak phase modulation, giving about 0.02 radians. Divide 0.02 by 2π × 10 MHz to obtain about 318 ps peak time deviation. The two interpretations can lead to different parts or corrective actions. The numbers illustrate the calculation. Separate modulation types in real measurements and state whether results are peak or RMS.
Use the same quiet source with known small AM and PM generated separately. Export the two demodulated traces from a phase-noise instrument or vector analyzer to verify the relevant channel responds to each stimulus. Known modulation lets you check AM leakage into the phase channel and whether the instrument settings are appropriate for the carrier and offset. Then connect the oscillator. Match output power to the analyzer’s allowed input range and reference level, and record lock and detrending settings. If the instrument cannot separate the two effects, report line offsets and discrete power pending a check with suitable equipment.
Relate the demodulation to the circuit
At a digital receiver, amplitude modulation can change the observed zero-crossing or threshold-crossing time. This is more apparent when the threshold sits away from the signal center, the slew rate is low, or a DC offset exists. Save a time-domain trace at the receiver and measure timing at the expected threshold. If demodulated PM is small but receiver crossings move periodically, compare threshold and bias under allowable conditions. If the source itself has repeatable PM, try alternate supply filtering or isolation. Compare at the same ripple at the device pin to distinguish reduced supply ripple from improved oscillator immunity.
Check units for lines and the continuous noise floor. A stable discrete line can be recorded as power relative to the carrier in dBc. A spectrum analyzer’s broadband noise marker normalizes by bandwidth to a per-hertz result. Placing that marker on a discrete line applies a resolution-bandwidth conversion and changes the meaning. Try two bandwidths narrow enough to resolve the sidebands. Observe how the line and nearby noise change and follow the instrument’s method to export discrete line power. Keep the two values separately so another instrument can reproduce the measurement.
If the measurement returns only envelope and crossings, use known pure AM to check unwanted response from the crossing detector. Use a separate phase measurement for samples closest to the limit. List discrete spurs, PM and AM separately along with carrier, offset, load and method. A supplier’s symmetric-sideband plot can substantiate spur locations and levels. A phase-jitter limit needs evidence from a phase channel or equivalent method, plus a statement of whether discrete spurs are included for the application.