Specialist Supplier of Crystals & Frequency Control Componentssales@mecxtal.com.cn0755-26500570
MERLIN home / Rednote / Passive Crystals and Oscillator Circuits

Can you determine passive crystal Q from the peak width measured on an assembled board?

A supplier's report assigns a quality factor above one hundred thousand to a 12 MHz quartz crystal. A laboratory sweep through a fixture gives a broader transmission peak and a much lower number. Before anyone rejects the shipment, check what each report measured. Energy dissipated in the crystal's motional branch, energy removed by the test fixture, and the performance of a feedback oscillator are three different quantities.

Estimate the expected width from motional parameters

Near series resonance for a single vibration mode, the crystal's motional branch is represented by a series resistance R1, inductance L1 and capacitance C1. The motional quality factor Qm is related to energy stored and lost in that branch. At motional series frequency fs, it is 2πfsL1/R1, or equivalently 1/[2πfsC1R1]. Both expressions assume the inductance and capacitance describe the same mode. Use hertz and farads, so 1 fF is 10⁻¹⁵ F.

Consider a hypothetical 12 MHz part with 2.2 fF of motional capacitance and 35 Ω of motional resistance under the same stated conditions. Its model gives a motional Q of about 172,246 and a motional inductance of approximately 79.96 mH. Dividing 12 MHz by that Q gives an ideal motional half-power width of about 69.67 Hz. If a typical capacitance has been combined with a maximum resistance from another specification column, the resulting estimate describes those inputs. Compare it to a guaranteed minimum Q only if the supplier actually offers that guarantee and the mode, drive and method agree. Analog Devices crystal model and quality factor · Keysight four-element equivalent analysis and half-conductance definitions

A different coupling arrangement can change the measured Q

For an isolated passive transmission peak dominated by one mode, a common estimate of the loaded Q is the center frequency divided by the full width between two half-power points. On a decibel transmission display, look about 3.01 dB below the peak on either side. A peak at −6 dB uses a half-power level of about −9.01 dB. Save both crossing frequencies, the peak and the axis definition. Impedance magnitude, antiresonance and conductance have their own measurement conventions. Keysight discussion of loaded Q and 3 dB bandwidth

Hypothetical 12 MHz partFull half-power widthResult
Fixture A with stronger coupling240 HzLoaded Q of 50,000
Fixture B with weaker coupling120 HzLoaded Q of 100,000
Calculation from the motional parameters aboveAbout 69.67 HzMotional Q of about 172,246

All three figures are illustrative. A coupled test circuit can draw energy from the resonator and broaden the peak. Calibrate each connection, check the drive that the crystal actually sees near resonance, and repeat before attributing a difference to coupling. If weaker coupling moves the peak close to the noise floor, the crossings may become difficult to identify. Improve the measurement range or adopt a validated de-embedding and equivalent-model method. The spectrum of an actively oscillating board output needs a different measurement. In particular, the apparent carrier width does not supply the passive transmission bandwidth for this calculation.

Set enough frequency resolution and settling time

Use a broad sweep to locate the main mode and any nearby responses, then narrow the sweep. A 500 Hz frequency step can skip across a peak that is only about 70 Hz wide. For that example, start with a step such as 5 Hz to locate both crossings, halve the step and check that the result repeats. Keep the span and point count with the trace. Also record intermediate-frequency bandwidth, averaging and sweep rate. With a high-Q resonator, a fast sweep can give an apparent peak shape that changes when the sweep is slowed or reversed. Repeat with adequate dwell or stepped acquisition if needed.

For an ideal linear single-mode response, the amplitude decay time constant is approximately Q/(πf). At 12 MHz and Q of about 172,246, this is 4.57 ms, and five time constants are about 22.8 ms. That gives an order of magnitude for the settling behavior. The instrument filter, the fixture's loaded response and the desired measurement error will determine a useful setting. If increasing dwell still changes the result, keep improving the measurement before interpreting small lot differences.

If repeated mounting moves the half-power width between 116 and 124 Hz while the center remains near 12 MHz, the calculated loaded Q spans roughly 96,774 to 103,448. That variation straddles a hypothetical acceptance limit of 100,000. Check contacts, mounting pressure and the calibration plane, then apply the agreed decision rule for an ambiguous result. Record mounting repeatability separately from the instrument frequency resolution before comparing lots.

Specify the parameter that answers the application question

For reliable cold startup with an MCU, ask for the maximum motional resistance at the actual frequency and vibration mode, and verify oscillator matching and startup on the board. For a narrowband filter, check insertion loss, terminations and passband directly. Identify the complete crystal code and lot, type of Q, drive, fixture and calibration plane, sweep settings, measured bandwidth and repeatability in the report. If the discrepancy only appeared after a fixture change, measure the same unit with the agreed method before opening a supplier investigation. The MERLIN guide to impedance sweeps and motional parameter extraction explains how to build an equivalent model from the resonant response.

WeChat

MERLIN · TIMING COMPONENTS

Scan with WeChat to contact Sales

Add our WeCom contacts from your usual WeChat app.

On desktop, scan with your phone. On mobile, save the QR image and select it from your album in WeChat Scan.