How many oscillators should you retain from each lot?

A production lot of oscillators goes to the contract manufacturer. Halfway through the build, intermittent failures begin. The warehouse retained the original reel label and two room-temperature test samples, but has no unsoldered units taken from known locations in the affected lot. The boards can still be analyzed, but parts from another lot offer a weaker comparison with the delivery in question. Decide which investigations the retained samples must support, then budget them by production lot, process state, and likely destructive testing. Whether the answer is three or thirty, record the reel, the treatment history, and the release date.

NDK's crystal handling guidance asks customers to preserve the failed condition where possible, suggests comparisons with a good board and component swaps, and requests details such as affected quantity, lot numbers, and photographs. SiTime's manufacturing notes explain reel labeling by lot and date code and permit two lots on some reels. These documents explain identification and failure reporting. The appropriate sample count for a project depends on the available analysis resources, order volume, process risks, and contract.

Retain units that can answer a specific question

List the comparisons you might need. To find out whether unused parts from the same lot operate correctly, save witness units directly from known original packaging with no reflow or return-shipment history. To investigate an assembly process change, keep a first-off or witness board that went through the normal process. To compare production lots, obtain a known earlier lot of the same relevant configuration. A similar-looking promotional sample does not supply a well-defined comparison. Add any customer-required test records and special samples to the same plan.

Before designating previously tested parts as references, record the tests they have seen. A room-temperature frequency check generally leaves the device available. Strong mechanical treatment, drive levels outside the allowed conditions, or repeated removal and soldering can change it. Keep those units separately from pristine witnesses. Choose sampling positions at receipt, before the only units left are the accidental tail of a run. Take separately labeled samples when reels are split, sources differ, or a process change divides production. If a two-lot reel has no confirmed boundary, record the limitation and ask the supplier for independently identifiable samples.

Whether to retain a piece of carrier tape depends on the problem. For suspected pocket crushing or cover-tape adhesion, preserve sections from good and suspect positions with their packaging information. To compare clock behavior after aging, document the assembled and unassembled samples as separate states. Photograph small part markings with a scale and accompanying label. If inventory cannot cover the entire test plan, agree on the laboratory and manufacturer sample requirements and prioritize the first investigation. A few units in several departments can quietly become the only usable reference if nobody tracks the relationship.

Worked example for two manufacturing lots

Suppose a purchase contains two identifiable lots, each delivered on two reels and destined for the same board. Assume the team needs three units per lot for basic electrical comparison, two for agreed destructive work, and two pristine witnesses. The reserve is seven per lot. If the project permits, take four from one reel and three from the other. Record their reel positions so the pristine references do not all come from the same one. The two lots require 14 loose parts in total. Two first-off process witness boards are a separate line item. Debit their devices through the work order, then avoid adding those same units to the 14-piece reserve.

Suppose the purchase is for 100 parts but engineering needs 100 complete boards. Holding seven witnesses creates a real shortage. Include seven retainers and the verified process consumption in the purchase quantity. If only 100 are available, ask quality about a smaller local reserve and a supplier hold. For the supplier-held units, confirm the exact production lot, remaining quantity, storage conditions, retention period, and request lead time. Without that information, estimate the investigation capacity conservatively. Small repair purchases can use the same arithmetic and choose reserves based on the value of equipment still in service and the quantities available.

Track custody and the eventual release

Use appropriate moisture and ESD protection and follow the manufacturer's storage conditions. The stock record should identify the manufacturer's part number, production lot, original reel, sample location, and completed tests. On the review date, check warranty coverage, any open complaints, and customer-approved changes. Extend the hold for material still under investigation and use the approved timetable for the rest. Separately identify units that have been soldered, removed, subjected to repeated reliability testing, or removed from their packaging. Tracking the pristine balance separately helps preserve the remaining usable evidence.

Record transfers between departments. For example, before sending a part for cross-sectioning, check whether it is the last pristine unit in its group and whether a different specimen with a known history would suffice. Update the quantity and test history when parts come back. When a new process or source lot enters the build, check that the physical reference stock covers the current configuration. Release legacy samples under the approved process when the project is retired. Finally, give the lot number to a colleague who did not inspect the original delivery. A successful drill should identify the right samples and show the original reel, storage history, and remaining balance.