A board carries a 25 MHz crystal, but its clock configuration has been copied from a 27 MHz design. All outputs toggle after power-up. The output intended to run at 10 MHz is near 9.26 MHz. Put the fitted crystal, the two schematics and the programmed register file side by side. An error of several percent calls for a check of the reference frequency and divider configuration first. Crystal loading can still matter and can be investigated once the reference and configuration are known.
The discussion applies to the XA and XB crystal inputs of the Si5351A/B/C-B. Section 4.1.1 of the manufacturer data sheet specifies a standard fixed-frequency AT-cut crystal at either 25 MHz or 27 MHz. On a design with a separate CLKIN path, check the full device number, schematic and source selection before deciding which input the design actually uses. Similar module names and markings do not establish the fitted variant or BOM.
Compare the relative error across the outputs
Suppose a locked clock chain with unchanged PLL and divider ratios was configured to generate 10 MHz from a 27 MHz reference. Fitting 25 MHz yields about 10 × 25 ÷ 27 = 9.259259 MHz, an error of roughly −740,741 Hz or −74,074 ppm. The reverse case, a 27 MHz crystal with ratios calculated for 25 MHz, yields 10.8 MHz, or +800,000 Hz. This example assumes a locked chain with fixed ratios. On the board, check the enables, selected source, PLL lock and frequency-counter reference.
With three outputs, record the ratio of measured to expected frequency on each. If they are all close to 25/27, check the reference entered when generating the configuration, then the production image and the effective register settings. If only one is wrong, start with that output's source, divider and enable, and check the reporting or counting software. Measure a buffered CLK output with its specified loading when possible. A high-capacitance probe on XA or XB can change the circuit running conditions.
Save the old image and the board identity before loading a different configuration. Compare on the same board with the same reference instrument and load. Establish which outputs are expected to be active at power-up before recording the steady-state values. Downstream parts may acquire a clock differently before and after reset, so one correct settled frequency does not establish startup behavior. In production, a board identifier should lead technicians to the actual programmed version and the previous image used for comparison.
Confirm load capacitance after the output ratio is correct
For quotes that both say 25 MHz and 3225, request each complete order code and specified load capacitance. Table 8 calls for the internal loading options for 6, 8 and 10 pF crystals. For a 12 pF crystal, the example uses 10 pF internally and adds a 4 pF capacitor to ground on each of XA and XB. The simplified external contribution across the crystal is 4 × 4 ÷ (4 + 4) = 2 pF. This explains the manufacturer's example. Board traces, pins, pads and test fixtures can introduce additional capacitance. The example should not be applied to other clock chips purely because they have internal capacitors.
The upper two bits of register 183 select the internal value. In the applicable register descriptions, AN619 and AN1234 list the 6, 8 and 10 pF settings, show 11 as the default upper bits corresponding to 10 pF, and mark 00 reserved. Use the map for the actual device/package and check the programming and fitted capacitors. A block diagram or a constant in a third-party library does not establish the permitted full-byte setting. Preserve when the firmware applies the write, whether it runs on cold boot, and what the readback shows.
Suppose an 8 pF variant was qualified with the internal setting at 8 pF and no external capacitors. A supplier now quotes a 12 pF unit with the same land pattern. Treat the proposal as a design change, listing the 10 pF setting, added loading capacitors and the test boundaries. Check whether both capacitor footprints exist and have reasonably similar routes. Complete the sourcing record with maximum ESR, load capacitance, permitted crystal drive-level rating, temperature conditions and the package drawing. For drive level, check the meaning of the 100 µW requirement in Table 8 against its parameter name and revision. Verify the crystal rating and actual in-circuit drive as separate facts.
Separate frequency calibration from replacement validation
If the actual reference is +20 ppm under one hypothetical condition, a fixed frequency ratio results in a 10 MHz output about 200 Hz high. Compare that scale with the earlier 740,741 Hz discrepancy when choosing what to diagnose first. A single room-temperature measurement of +200 Hz does not identify the cause. Initial crystal tolerance, incorrect load, temperature, reference accuracy and assembly differences can all contribute. Use a verified counter reference and identical warm-up, gate time and load. Compare a control board with the approved component and a candidate board under the same configuration.
Where the system permits frequency calibration, store it by board identity and confirm that the resulting frequency fits the budget across the target temperature range. Calibration corrects an offset under the defined conditions. Review startup time, loss of lock, sequencing and drive against separate cold-start, reset and voltage/temperature results. With samples from independent lots, keep the crystal and IC order codes, image version, register readback and board position on each test record so that later maintenance can identify what changed.
The handoff has two decision points. If the error is still several percent, the evidence should establish the selected source and actual configuration. If both crystals give a plausible output at room temperature, compare the startup and temperature extremes. Purchasing records the full orderable part number and delivery requirements. Engineering records the fitted loading and approved register configuration against the same item so an incompatible crystal and firmware combination can be stopped before shipment.
Manufacturer references
- Skyworks Si5351A/B/C-B data sheet, Table 8, Section 4.1.1 and Figure 2.
- Skyworks AN551 crystal selection guide, internal and external loading.
- Skyworks AN619 register map and the AN1234 map for 16-QFN, register 183.