Does a one-second startup timeout work for a 1 Hz SiT1581?

A battery-powered logger originally used a faster external clock on the bench. The design moves to a factory-programmed 1 Hz oscillator but retains the same firmware timeout. If no edge arrives within one second, firmware reports an external clock fault and switches to its internal timebase. Some starts seem to work. The availability of a 1 Hz option does not answer how long the first 1 Hz output pulse can take.

The SiTime SiT1581 Rev 2.01 datasheet gives different power-up startup specifications by frequency. For 1 to 10 Hz, the upper limit to the first output pulse is 500 milliseconds plus three output periods. Above 10 Hz through 200 Hz, it is 300 milliseconds plus two and a half periods. The starting point is when the device supply reaches 90% of its final value, with the stated output-frequency conditions. Page 6 presents frequency ordering in kHz, so 1 Hz is represented by 0000.001000. Check the timing table and ordering instructions independently.

Put the period term in seconds

At 1 Hz, a period lasts one second. The stated limit is therefore 3.5 seconds. At 10 Hz, the period is 100 milliseconds and the same expression gives 0.8 seconds. At 20 Hz the other row applies. Its 50 millisecond period gives 425 milliseconds in total. These are limits as stated for the relevant ranges. A typical startup that happened sooner does not eliminate the period term. A project requiring the first valid 1 Hz edge within two seconds cannot rely on the given limit to prove coverage.

The equipment may start its timer earlier than the device specification. If 180 milliseconds elapse from the power-switch command until the actual oscillator rail reaches 90%, those two components already total 3.68 seconds at 1 Hz. Check the downstream reset and whether its input is enabled. A late reset release can cause firmware to miss the oscillator's real first pulse, extending the observation to another period.

A one-second retry that also cycles power can keep the oscillator from ever completing a conforming startup. Record each supply event and firmware reset reason. Determine whether the observation window was cut short or the rail collapsed. To verify the actual frequency, use a separate interval long enough to measure it from more than one edge.

Capture four signals on one time axis

Record oscillator supply at the device, its output, downstream reset release, and a firmware indication of the observed edge. Trigger from the board's power event when convenient, then measure the offset to the 90% crossing. For a slow ramp or overshoot, define the final voltage used for that calculation. Note the instrument's edge threshold if it differs from the real receiver threshold. Record the probe and its added load, especially on low-power circuitry.

Run a fully discharged cold power-up, a brief interruption followed by restart, and an MCU reset while oscillator power remains on. All three might appear as restarts in a log. Only some require the oscillator itself to start. A valid edge soon after the MCU-only reset says little about the cold case. Record minimum rail voltage and how long it discharged so the states can be reproduced.

Keep the ordering field separate from the equipment deadline

Check the complete option code and confirm 1 Hz rather than 1 kHz before releasing an order. Page 6 lists code 18 as 1.8 V and limits codes 33 and YY to 32.768 kHz. Verify the complete supply and temperature specification for the ordered frequency. Describe the engineering requirement as a measured interval from the agreed power event until the system recognizes a stable edge, with an allowance for a missed first cycle if appropriate. Preserve the complete purchasing code and the four synchronized observations. If the equipment cannot tolerate the specified window, change the design's startup rules or qualify a different solution before setting a production rejection rule.