A SiT1602B 48 MHz active oscillator can be ordered with pin 1 set to output enable, standby or no function. All three may pass a bench check that only applies power and measures frequency. In service, one board may need fast clock recovery, another may need microamp standby, and a third may leave pin 1 floating. Record the feature with the complete ordering code so the first indication of an incorrect part does not come during system wakeup or a sleep-current measurement.
See what each option does with pin 1 low
SiTime describes output enable as disabling only the output driver when pin 1 is low. The output goes high impedance and the oscillator core continues running. The standby part puts its internal circuitry to sleep and weakly pulls the output low. Both can look like a stopped clock, but the high-impedance output may be affected by a receiver pull-up or another driver. The no-function option continues to provide the clock after normal power-up regardless of the control logic. Identify output enable, standby or no function explicitly on the material record.
The ordering guide uses E for output enable, S for standby and N for no function in the feature-pin position. It also encodes output drive, temperature, voltage, frequency stability and packaging. Check the actual field. An E appearing anywhere in a part number is not proof of output enable because other positions can carry the same letter. Keep the manufacturer's complete ordering description with the sample record and add testable startup, disabled-state and load fields to the production purchase specification.
Convert the receiver deadline into an oscillator requirement
The data sheet gives frequency-dependent output-enable timing. Away from the frequency shown in the table, use 100 ns plus three clock cycles. At 48 MHz each cycle is about 20.83 ns, giving 162.5 ns. Standby recovery can take up to 5 ms after pin 1 crosses the stated threshold. Power-up startup also has a separate 5 ms maximum. Suppose a receiver needs stable clock within 50 µs of releasing the control pin. With oscillator power continuously valid, the OE option can advance on timing, whereas the standby guarantee exceeds the deadline. If the rail is switched off in sleep, qualify power-up startup rather than using the OE time.
Do not borrow a current value from the wrong condition. The manufacturer's comparison includes an OE-disabled maximum at 20 MHz and 1.8 V and a typical standby current. The conditions and statistical definitions differ. For a battery budget with a 48 MHz active oscillator, confirm the actual supply and temperature and agree on conservative usable values. If the clock branch has a 10 µA sleep limit, the version in which the core keeps running needs measured and specified current. It cannot use the standby variant's microamp figure. Check whether standby recovery requires a revised system wakeup sequence.
SiTime recommends a pull-up of 10 kΩ or less for an undriven OE or standby pin and specifies the no-function option when the pin must float. A processor's output can be high impedance during reset or come from another rail. Verify the pull-up supply, logic levels and power sequence using both data sheets. For example, at a 3.3 V oscillator rail, the control input's 70% high-level condition corresponds to 2.31 V. A controller guaranteed to produce only 1.8 V cannot establish a valid high directly. After the interface is revised, retest the receiver waveform and timing.
Decide what captures belong in incoming acceptance
Check the ordering code, then measure frequency and swing on a fixture with the approved supply and load. Capture pin 1, supply and output together for both control transitions. If the processor enters high impedance at startup, repeat on a board representing that condition. To distinguish a floating output from a static level due to a pull-up, use an engineering-approved load and measurement. A flat high trace does not supply valid clock edges. A low-power current report should identify the mode and the settling time before measurement.
If the receiver can also be connected to a second clock, verify on first articles that both sources cannot drive the same line at once. The disabled OE output is high impedance, standby has a weak pull-down, and the no-function version cannot release the line through pin 1. Check sequence, levels and receiver thresholds before approving a shared line. Check the real idle state in production because a bench with only one source can obscure the difference. If a buffer or switch isolates the sources, document the installed components and their control conditions.
Specify the full 48 MHz active oscillator ordering code, pin function, temperature and packaging. For a receiver with a short start window, put the control-to-valid-output maximum and frequency criterion on the acceptance sheet. If the priority is sleep current, check worst-case recovery and verify that the actual sequence reaches standby. A different feature letter on arriving material means hold it for alternate approval. A successful frequency check does not qualify it for the same production lot.