Turning a SiTime custom 50 MHz oscillator addendum into a purchase order

Purchasing sees SiT8924B-73-0016 on a drawing without an explicit frequency or familiar voltage and temperature fields. The supplier offers a standard-format SiT8924 code. Both quotes mention 50 MHz, 1.8 V, and a small four-pin package. Check the manufacturer’s custom addendum first, then compare the exact standard-code page. This SiTime 50 MHz oscillator uses a MEMS resonator. Specify it as a MEMS active oscillator in the RFQ. This also prevents a quote for a quartz oscillator based only on package and frequency.

The addendum specifies the custom configuration

SiTime’s addendum identifies SiT8924B-73-0016 as 50.000000 MHz, silicon revision B, nominal 1.8 V, −40 to +125 °C, 2.0 × 1.6 mm, default output drive, and output enable. Frequency stability is ±50 ppm. The published SiT8924BA-72-18E-50.000000 page lists another 50 MHz part with the same supply, temperature range, package, and enable function. It specifies ±25 ppm. A family feature lower on the page mentions 20 ppm, but the exact configuration section controls the comparison. Put the custom and standard codes on separate quote lines with their respective evidence.

Read suffixes by position. The custom addendum gives SiT8924B-73-0016D as an order example. D means 8 mm tape with 3,000 per reel, E means 1,000 on the same tape width, and blank is bulk for sampling only. In the standard format the E in 18E refers to output enable. Packaging comes after the stated frequency when ordered in the appropriate format. For a 6,000-piece work order, two custom D reels or six E reels supply the same quantity but require different feeder and return records. Use the complete ordering code and actual packaging confirmation to plan production.

Compare the frequency allowances of two equal nominal frequencies

For this 50 MHz MEMS oscillator, ±50 ppm is ±2,500 Hz and ±25 ppm is ±1,250 Hz. If a design allocates ±1,500 Hz to the oscillator, the standard code leaves 250 Hz and the custom limit exceeds the allocation by 1,000 Hz. A custom sample reading 500 Hz high may support a trial. It does not establish a ±25 ppm shipping limit. Before adding supply, clock-chain, and instrument terms, review which effects the base specification already includes.

The base 1.8 V option spans 1.62 to 1.98 V. Suppose a ±5% board regulator has a 1.71 V minimum. A 40 mV distribution drop gives 1.67 V at the device, leaving 50 mV. If a startup reading of 1.65 V has ±20 mV uncertainty, its lower extent is 1.63 V, within the range in this example. Agree on the actual acceptance rule in advance. Test voltage, load, enable state, and temperature on the same samples so a wrongly specified voltage version that operates on the bench does not inadvertently pass qualification.

Check the measurement decision around the tighter limit. For a 1,250 Hz limit, a reading of +1,220 Hz with 40 Hz expanded uncertainty reaches +1,260 Hz. Under an agreement that requires the full interval to be within the limit, retest with lower uncertainty or agree how to handle the remaining risk. Keep the raw reading in hertz, counter reference, environment, and effective gate time. Rounded ppm values make a borderline result harder to audit against both grades. These records also help distinguish an order based on known electrical and packaging specifications from a quote that only includes some loose sample results.

Retain both documents behind the short receiving code

Receiving can enter the shortened part number from the reel label, but the approval record should attach the relevant revisions of both the original addendum and the base data sheet. Confirm the short number, packaging suffix, and specification revision before taking room-temperature data at the agreed voltage. If a standard-format part is proposed as a substitute, review technology, board-level enable, startup, jitter, and the system frequency budget. A similar name and a tighter figure in one row do not establish full substitution. Tie an unreeled sample to its engineering order. Later volume purchase needs D or E and the applicable reel count and feeder check.

If the receiver only has a printed part label, provide the manufacturer identification rules and preserve the original label image during splitting. For an independently assigned supplier code, obtain its mapping to the original manufacturer part number, lot, and packaging suffix.

Products that accept different frequency grades can maintain different approved uses. If the fixture can screen ±25 ppm but production only runs a room-temperature frequency check, engineering needs to decide which voltage and temperature corners require qualification. Do not merge the custom and standard codes automatically without manufacturer evidence of equivalence. If both trial pieces pass, retain both raw results, their labels, and board IDs. That record lets purchasing identify whether a later proposal is a packaging change, a stability-grade change, or an addendum associated with the wrong item.