Why does each SN6505B switch run at 420 kHz with an 840 kHz sync clock?

An isolated acquisition board uses an SN6505B and transformer. The team plans to synchronise the supply to a board clock so switching energy falls at a defined frequency. The analyser sees 840 kHz at CLK, but one power switch repeats at only 420 kHz. On power recovery the spectrum changes again. Record where and when each measurement was taken. The external reference, an individual push-pull switch and a peak in the full noise spectrum represent different quantities.

One input clock drives alternating switches

The SN6505B datasheet describes using the rising CLK edges to divide by two and drive the push-pull stage. D1 and D2 alternate. An 840 kHz input has a period of about 1.190 µs. The same action at one drain recurs after two input periods, about 2.381 µs, giving 420 kHz per switch. Counting alternating events from both outputs gives a different number. The report should say whether a frequency belongs to CLK, one drain or the rectified secondary ripple. Modulation, rectification, load and layout also affect the spectrum. TI SN6505x Rev. I, section 8.4.5 and Figure 9-2

The SN6505B supports an external CLK range of 100 to 1600 kHz. The A version specifies 100 to 600 kHz and has a different internal operating frequency. Verify the clock before using an A version in place of a B. An 840 kHz input fits the B range and exceeds the A limit. Even with matching footprints, check both the external input and fallback behaviour. TI's SN6505B evaluation module includes provision for feeding an external clock and provides a concrete circuit to inspect. TI SN6505x electrical clock characteristics TI SN6505BEVM evaluation module with external clock input

Verify the derived board clock at the physical input

Suppose the board already has a 25.200 MHz oscillator and divides it so that a complete CLK period spans 30 reference periods. The result is 840 kHz at CLK. With the same topology and a 24.000 MHz source, CLK becomes 800 kHz and each switch drops from 420 to 400 kHz. If a previous design reserved a frequency region for a signal or filter, measure the effect of that 20 kHz move. Define the division in complete periods. Toggling only once per 30 input clocks would divide by two again.

If the original 25.200 MHz part is unavailable, evaluate where to change the design. An exact 840 kHz output from 24.000 MHz needs division by about 28.571, which is not a single integer period count. Divide-by-28 gives approximately 857.143 kHz and divide-by-29 gives approximately 827.586 kHz. Check both against the permitted switching band. If a programmable source uses fractional division, verify adjacent periods and pulse width as well as mean frequency.

Check logic levels after calculating the rate. The datasheet defines CLK switching thresholds relative to the supply. With the driver on 5 V and the clock rising only to 3.3 V, a square waveform alone does not establish that the 0.7 × VCC threshold is met. That calculation gives 3.5 V. Check the part's low level, amplitude and edge quality at the receiver, plus rail sequencing. If a translator is needed, confirm the CLK pin stays at a defined level when the source is disabled. TI SN6505x EN and CLK switching thresholds

Relate the transformer volt-second specification to the switch timing. At the same supply and with the same winding, a longer effective on-time at a lower rate increases volt-seconds per half-primary. Dropping from 420 to 400 kHz increases on-time by about 5% at a fixed ideal duty ratio. Actual behaviour includes dead time, drive shape and supply changes. Verify the result against the transformer specification and measured current. The driver's allowable clock range by itself does not qualify the transformer or output filter across that range. TI SN6505x transformer selection and timing

Test synchronised operation, fallback and the transitions

When valid external CLK disappears, the device falls back to its internal clock after tCLKTIMER. The timing table gives bounds of 10 to 25 µs. The internal spread-spectrum emissions feature is disabled while an external clock is present. If the board clock disappears first, isolated power can continue in a different spectral state. The spectrum changes again when synchronisation returns. With driver supply and EN maintained, stop and restart the clock and observe D1, D2 or other suitably isolated points. Save output ripple, load voltage and the frequency band the system needs to protect. Actual transient ripple requires a board measurement. TI SN6505x Rev. I, sections 6.6 and 8.4.5

Turn the timeout into a capture scale. An 840 kHz period is about 1.190 µs, so 10 to 25 µs span the time of roughly eight to twenty-one original CLK periods. That guides the capture length and does not imply a number of output pulses during fallback. Trigger on the last external rising edge and save enough complete cycles before and after the transition. Check for a temporary output-voltage dip under load and capture recovery after the external source restarts separately.

If a spectrum peak controls acceptance, keep the same bandwidth and sweep settings for both modes. Distributed modulation energy and a narrow fixed peak need a consistent measurement method. Observe the no-load and typical-load structure, then test the required load endpoints. For multiple converters, align records to the measured input reference so the effect of synchronisation can be distinguished from supply and wiring differences between units.

For several nearby converters sharing a reference, also consider whether coincident switching concentrates peaks. TI's public technical discussion of power supply synchronisation relates beat frequencies and input ripple, giving concrete conditions to compare in time and frequency. Keep load, probes and ground connections consistent while saving internal, externally synchronised and fallback captures. Give sourcing the complete oscillator code, source frequency, division, CLK voltage domain and qualified rate in both clock states. A later change between 24 MHz and 25.200 MHz can then be traced from switching behaviour back to the actual order. TI technical discussion of synchronised power modules and beat frequencies