How should an order set ESR for TXC AB passive crystals at 20 MHz and 40 MHz?

Two boards use the TXC AB family in a 5032 outline. One needs a 20 MHz passive crystal and the other needs 40 MHz. The public ESR table gives adjacent frequency ranges with a shared boundary at 20 MHz. If the circuit requires the tighter limit at that point, ask for the guarantee for the exact ordering code before copying it into inspection. The 40 MHz part falls in the upper band, but the two builds still require separate electrical material records even when they share the package.

Obtain the part-specific guarantee at the boundary

TXC lists AB as a 5.0 × 3.2 mm automotive MHz crystal family covering 8 to 50 MHz. The public ESR table lists 80 Ω maximum for 12 to 20 MHz and 60 Ω maximum for 20 to 50 MHz. The printed range separator does not resolve which row governs exactly 20 MHz. Do not infer that a 20 MHz candidate has the tighter guarantee. Resolve the question at RFQ instead of at incoming inspection. Include the data sheet revision, frequency, project limit and temperature, and ask the manufacturer or supplier to confirm the ESR applicable to the complete ordering code. A copy of the family page alone does not resolve the boundary.

Suppose the 20 MHz crystal circuit has a 70 Ω purchasing limit. A formal 60 Ω guarantee leaves 10 Ω, while an 80 Ω guarantee is 10 Ω over budget. A 57 Ω reading on one sample cannot replace the lot guarantee. Compare the approved part and candidate under equivalent fixture, drive and temperature and obtain the applicable maximum. If the lower range is a special grade, retain the full orderable code or written condition linking it to shipments. A good sample lot does not establish subsequent material variation.

Keep the electrical requirements separate when the footprint is shared

The 40 MHz passive crystal falls inside the 20 to 50 MHz band, so 60 Ω is useful for screening from the public table. Use the exact part's conditions for acceptance. The family sheet also lists selectable load capacitances such as 8, 10 and 12 pF, a drive row and stability over several operating ranges. The outline, terminal and footprint drawings may be shared in a controlled document, but specify separate frequencies, loads, drive and acceptance limits. Where the reel labels share AB and a similar date, store by complete part number and have production verify the frequency for the selected board.

At 20 MHz, 1 ppm is 20 Hz. At 40 MHz it is 40 Hz. The family table's example ±10 ppm initial tolerance corresponds to ±200 Hz and ±400 Hz. Stability over temperature is separate and referenced to room temperature. If an exact approved grade adds ±30 ppm temperature stability, worst-case initial and temperature terms sum to ±40 ppm. That is approximately ±800 Hz and ±1,600 Hz, before other terms such as board loading. State whether a measurement uses nominal frequency or the sample's room-temperature baseline. They support total-error and temperature-drift decisions respectively.

Compare production samples to the correct baseline

At receiving inspection, verify labels, the specification revision and fixture conditions. Measure the candidate under the agreed temperature, drive and rated load. An ESR report using another drive condition needs an equivalent comparison. PCB parasitics and oscillator gain add separate concerns. On a production-representative board, check startup at hot and cold temperatures and low supply, running frequency and drive, and record the components installed around the crystal. Keep a known-good baseline board for each version. If a new lot fails to start, identify the delivered and installed crystal before attributing the issue to the oscillator or its circuit.

Define how receiving should treat measurement uncertainty near the limit. Suppose the ESR limit is 70 Ω, one part measures 68 Ω, and the lab gives ±3 Ω expanded uncertainty. Under a guard-band decision that retains the unfavorable endpoint, the result could reach 71 Ω and should be held for the approved retest. Design budget, supplier guarantee and instrument uncertainty serve different roles. Check fixture calibration, contact and test frequency. If supplier and receiving results use different fixture definitions, look for a systematic difference. Save conditions along with the result so later reports can be compared correctly.

TXC also lists first-year and longer-horizon aging separately. Use the applicable service interval when allocating error. Do not extrapolate the short-term number as if it were a lifetime guarantee. If a supplier proposes a change, preserve the approved temperature, test method and time definition. Keep short-run sampling evidence and the long-term guarantee separately traceable. Retain reel identity and lot tracking for repair parts returned from an opened production reel.

Order the 20 MHz and 40 MHz crystals under complete separate codes with their load, temperature, drive and ESR. Record which written maximum applies to the 20 MHz boundary. Release 40 MHz against its own fixture frequency and assembly. A candidate with only the family and footprint confirmed needs more information before release. Separate records let both production and repair apply the correct conditions for the installed part.