Specialist Supplier of Crystals & Frequency Control Componentssales@mecxtal.com.cn0755-26500570
MERLIN home / Rednote / Measurement and Acceptance

A 32.768 kHz crystal still runs after ultrasonic cleaning. Can the process be released?

A 32.768 kHz watch crystal starts after soldering. After ultrasonic cleaning and drying, the same board still keeps time. Production is ready to release the next lot, while someone points out that a problem might appear only at the next low-voltage or cold start. Cleaning qualification asks two questions. Is the process acceptable for the exact order code? Do the resonator and oscillator circuit retain the required start-up margin after processing? Measuring frequency on an already-running board answers only a small part of either question.

The drawing specifies a watch crystal. The process sheet specifies a cleaning bath.

Epson’s crystal device handling precautions distinguish AT-cut devices from tuning-fork products. The manufacturer permits cleaning of the first group subject to verification and warns that characteristics or internal connections can be damaged. It says it cannot guarantee products using tuning-fork crystals after ultrasonic cleaning, which can damage the crystal. Section 2-3 of NDK’s precautions for crystal units also discusses degradation if the cleaning machine excites a resonator and calls for checking the mounted board. Apply each manufacturer’s guidance to its own part numbers. If the part documentation restricts the process, a small zero-failure trial cannot override that restriction.

The buyer should send the full order code, PCB revision, cleaner and fixture, nominal frequency and operating mode, known power settings, bath chemistry and temperature, immersion depth and cumulative exposure time. Include actual scenarios such as a second clean or cleaning after rework. The cleaner’s nominal frequency describes only part of the setup. The local acoustic field also depends on transducers, liquid level, racks, board count and placement. The numerical difference between the cleaner’s nominal frequency and 32.768 kHz cannot establish a universal safe separation. For unconfirmed parts, keep ultrasonics pending and validate a cleaning process suitable for the full bill of materials and production requirements.

When permitted, use three groups to separate chemistry from ultrasonic exposure

GroupTreatmentQuestion answered
Retained controlsSame reflow lot and elapsed time, no washHow much change comes from assembly or waiting?
Bath controlsMatch immersion, temperature and drying where equipment and chemistry permit, with ultrasonics offCan liquid, heating or drying explain the difference?
Production processRun the proposed ultrasonic process at the designated positions and maximum permitted cumulative exposuresDoes the complete production path change start-up or crystal response?

Distribute panel positions and crystal lots across the groups. Identify and measure each board before it enters the bath. If both washed groups deteriorate, check cleaning chemistry, residue or drying first. If only the actual production process creates a consistent difference, investigate ultrasound and positioning. Base the conclusion on paired before-and-after board readings where possible. Putting the poorer reflow boards in one group and comparing group averages can misattribute an assembly difference to cleaning. Preserve failed production boards and same-reel samples as received. Log any later drying, touch-up or crystal replacement for failure analysis.

Two measurements determine whether to investigate further

The first is cold start-up time and success rate under specified conditions. Observe a buffered clock output or a verifiable software status. Record the supply ramp, minimum operating voltage, temperature and restart timing after complete power removal. On a controller with a backup oscillator, also read the active clock source or failure flag. A once-per-second interrupt may show that the fallback clock is running. When there is no buffered output, follow the IC guidance for non-contact observation so that probing the crystal pin does not change its load.

The second is crystal loss and start-up margin. Measure equivalent series resistance (ESR) on same-lot witness devices in a separate fixture following the manufacturer's definition, with matched drive and temperature. For board-level margin, Section 4.2 of TI SLAA322D describes a series-resistor test. Use a dedicated board to find the largest added resistance RQmax that still allows start-up. In an example at one temperature, ESR is 60 kΩ and RQmax is 240 kΩ. The ratio is (240+60)/60 = 5.0. If the other group’s witness devices have 85 kΩ ESR and the corresponding boards tolerate only 160 kΩ, the ratio is about 2.88. Running frequency can still be within tolerance while the change in start-up margin calls for investigation. The numbers are illustrative. Set the threshold in advance according to the controller, crystal and board test requirements.

Ten power cycles on one board can expose an intermittent problem on that board. For lot coverage, count independent physical boards as independent samples. The ten cycles do not equal ten boards. For example, assuming independent and identically distributed random samples, zero failures in 30 boards gives a one-sided 95% upper failure-rate bound of 1−0.051/30, about 9.5%. That is a bound under the sampling model, far from a production defect-rate commitment. Demonstrating a low defect rate requires enough samples that represent the manufacturing conditions.

If the witness ESR rises materially and mounted boards also start more slowly, preserve affected crystals for supplier impedance sweeps and failure analysis. If loosely mounted witnesses look normal but production boards differ, continue investigating mounted-board stress, soldering and local wash conditions. The two mounting arrangements receive different vibration. Witness devices help locate the problem and cannot establish the condition of mounted crystals by themselves. A sudden frequency shift without an obvious loss change also calls for checking contamination and loading on the PCB.

Record the qualification on the process sheet

Record the exact order codes and lots, board count in each group, bath conditions, before-and-after frequency and cold start-up, witness ESR, permitted rewashes during rework and how production verifies the approved settings. When changing the machine, chemistry, rack, PCB or crystal order code, check that the qualification still covers the new combination. If temperature corners and long-term effects belong to a separate qualification plan, the production record should trace to it. Purchasing then has conditions that can be repeated on the next lot, and production can identify changes that call for fresh samples.

WeChat

MERLIN · TIMING COMPONENTS

Scan with WeChat to contact Sales

Add our WeCom contacts from your usual WeChat app.

On desktop, scan with your phone. On mobile, save the QR image and select it from your album in WeChat Scan.